Sewer defect codes & the 1–5 pipe condition grade

This is the exact code list the generator applies to your field notes. Codes, severities and the pipe grade are computed by fixed rules — not by the language model — so the same defect always gets the same code, severity and grade.

Structural codes (S-) — repairs

CodeDefectCategory
S-OJOffset JointStructural (repair)
S-JSJoint SeparationStructural (repair)
S-CRCrackStructural (repair)
S-BRBroken PipeStructural (repair)
S-CLCollapseStructural (repair)
S-DFDeformation / OvalityStructural (repair)
S-WRWrinkle / Liner DefectStructural (repair)
S-DTDeteriorationStructural (repair)
S-OBOrangeburg DeteriorationStructural (repair)
S-VDVoid / Soil IntrusionStructural (repair)

Operation & maintenance (M-) and condition (C-) codes

M- codes are maintenance items. C- codes are conditions worth recording without being defects (a material transition, a sonde/tap marker, or a clean run).

CodeDefectCategory
M-RRoot IntrusionO&M (maintenance)
M-GGrease BuildupO&M (maintenance)
M-DBDebris BlockageO&M (maintenance)
M-SCScale / TuberculationO&M (maintenance)
M-WStanding Water / BellyO&M (maintenance)
M-IIInfiltration / InflowO&M (maintenance)
M-SDSediment / GritO&M (maintenance)
C-MTPipe Material TransitionO&M (maintenance)
C-SNSonde / Tap MarkerO&M (maintenance)
C-OKNo Significant DefectsO&M (maintenance)

Severity thresholds

SeverityWhen it appliesTypical grade
MinorNo meaningful loss of flow capacity — observation only1–2
ModerateRoughly 10–25% loss of cross-section, or fix within 12 months3
MajorRoughly 25–50% loss of cross-section, or fix now4
CriticalOver 50% loss, collapse, or soil entering the line5

How the 1–5 grade is derived

The grade is driven by the worst finding on the run: a structural defect counts double, and the result is clamped to 1–5. The model's own opinion never sets the badge — you can override any severity, and the report records that you did.

GradeLabel
1Excellent
2Good
3Fair
4Poor
5Immediate Attention

See a full sample report